NASN POWER
6kW~12kW
80%
IP65
Three phase 220/230/380/400 Vac
Availability: | |
---|---|
Hybrid inverters support bi-directional power flow, enabling energy to be both, imported from the grid and exported to the grid or stored in batteries.
Hybrid inverters have built-in battery management systems that allow them to charge and discharge batteries, storing excess solar energy for use during peak demand or grid outages.
Hybrid inverters can operate independently of the grid during power outages, allowing homeowners to have access to backup power when the grid is down.
Hybrid inverters are generally more expensive than standard solar inverters due to their added functionality and capability to handle battery integration.
Hybrid inverters can optimize energy usage by shifting loads to periods with lower electricity costs (e.g., during off-peak hours) when grid electricity rates are lower.
Hybrid inverters provide advanced energy management features, allowing users to monitor and control energy consumption, solar production, and battery storage for better energy efficiency.
Hybrid inverters can operate in off-grid mode, making them suitable for remote locations or areas without access to the utility grid.
MODEL | SH48V6KWS | SH48V8KWS | SH48V10KWS | SH48V12KWS | SH48V6KWT | SH48V8KWT | SH48V10KWT | SH48V12KWT | |
Input | |||||||||
PV | Max input power | 7.8kW | 10.4kW | 13kW | 15.6kW | 7.8kW | 10.4kW | 13kW | 15.6kW |
Input Voltage | 370V (125V~500V) | 550V (160V~800V) | |||||||
Max input current | 13+13 | 20+20 | 26+26+26 | 26+26+26 | 13+13 | 26+13 | |||
Charge mode | MPPT | MPPT | |||||||
No. of MPPT Trackers | 2 | 3 | 2 | ||||||
No. of Strings Per MPPT Tracker | 1+1 | 1+1+1 | 1+1 | ||||||
Rated input voltage | 370Vdc | 550Vdc | |||||||
Vmp Range | 150~425Vdc | 200~650Vdc | |||||||
Battery | Type | Lead-acid or Li-Ion | Lead-acid or Li-Ion | ||||||
Battery Voltage Range(V) | 40-60 | 40-60 | |||||||
Max discharge current(A) | 135 | 190 | 220 | 250 | 120 | 160 | 200 | 240 | |
AC&Generator | Input voltage | Single phase 220/230 Vac | Three phase 220/230/380/400 Vac | ||||||
Frequency | 50-60Hz | 50-60Hz | |||||||
Rated Current(A) | 27.3 | 36.4 | 45.5 | 54.6 | 9.1 | 12.1 | 15.2 | 18.2 | |
Max Current(A) | 30 | 40 | 50 | 60 | 10 | 13.4 | 16.7 | 20 | |
Output | |||||||||
AC output | Rated capacity | 6kW | 8kW | 10kW | 12kW | 6kW | 8kW | 10kW | 12kW |
Max capaicty | 6.6kW | 8.8kW | 11kW | 13.2kW | 6.6kW | 8.8kW | 11kW | 13.2kW | |
Output voltage | Single phase 220/230 Vac | Three phase 220/230/380/400 Vac | |||||||
Frequency | 50/60Hz | 50/60Hz | |||||||
Rated Current(A) | 26.1 | 34.8 | 43.5 | 52.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
Power factor | 0.8 | ||||||||
Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | |
Transfer time(AC to DC) | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | |
Transfer time(DC to AC) | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | |
Output voltage regulation | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | |
Bypass Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Saver Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
On grid Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Efficiency | >95% | >95% | >95% | >95% | >95% | >95% | >95% | >95% | |
DC output UPS mode | Charging Strategy for Li Battery | Self-adaption to BMS | Self-adaption to BMS | ||||||
Max charging current | 135 | 190 | 220 | 250 | 120 | 160 | 200 | 240 | |
GENERAL | |||||||||
Display | LCD display | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC |
Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | ||
Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | ||
Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | ||
Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | ||
LED Indicator status | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | |
Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | ||
Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | ||
Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | ||
Interface | Communication | CAN | CAN | ||||||
Parallel | Max support 10pcs | Max support 10pcs | |||||||
Wifi | External | External | |||||||
Dry contact | For generator input | For generator input | |||||||
Environment | IP grade | IP65 | IP65 | ||||||
Temperature | -25~60℃ | -25~60℃ | |||||||
Cooling | Smart Cooling | Smart Cooling | |||||||
Accoustic Noise(db) | <55dB | <55dB | |||||||
Mechanical | Size | 346*506*255mm | 426*526*255mm | 446*576*254mm | 446*576*254mm | 446*576*254mm | |||
Carton dimension | 530*600*300mm | 530*600*300mm | 630*900*380mm | 630*900*380mm | 630*900*380mm | ||||
Net Weight | 24KG | 29KG | 31KG | 32KG | 37KG | 39KG | 41KG | 42KG | |
Gross weigth | 28KG | 34KG | 36KG | 37KG | 42KG | 45KG | 48KG | 50KG |
Hybrid inverters support bi-directional power flow, enabling energy to be both, imported from the grid and exported to the grid or stored in batteries.
Hybrid inverters have built-in battery management systems that allow them to charge and discharge batteries, storing excess solar energy for use during peak demand or grid outages.
Hybrid inverters can operate independently of the grid during power outages, allowing homeowners to have access to backup power when the grid is down.
Hybrid inverters are generally more expensive than standard solar inverters due to their added functionality and capability to handle battery integration.
Hybrid inverters can optimize energy usage by shifting loads to periods with lower electricity costs (e.g., during off-peak hours) when grid electricity rates are lower.
Hybrid inverters provide advanced energy management features, allowing users to monitor and control energy consumption, solar production, and battery storage for better energy efficiency.
Hybrid inverters can operate in off-grid mode, making them suitable for remote locations or areas without access to the utility grid.
MODEL | SH48V6KWS | SH48V8KWS | SH48V10KWS | SH48V12KWS | SH48V6KWT | SH48V8KWT | SH48V10KWT | SH48V12KWT | |
Input | |||||||||
PV | Max input power | 7.8kW | 10.4kW | 13kW | 15.6kW | 7.8kW | 10.4kW | 13kW | 15.6kW |
Input Voltage | 370V (125V~500V) | 550V (160V~800V) | |||||||
Max input current | 13+13 | 20+20 | 26+26+26 | 26+26+26 | 13+13 | 26+13 | |||
Charge mode | MPPT | MPPT | |||||||
No. of MPPT Trackers | 2 | 3 | 2 | ||||||
No. of Strings Per MPPT Tracker | 1+1 | 1+1+1 | 1+1 | ||||||
Rated input voltage | 370Vdc | 550Vdc | |||||||
Vmp Range | 150~425Vdc | 200~650Vdc | |||||||
Battery | Type | Lead-acid or Li-Ion | Lead-acid or Li-Ion | ||||||
Battery Voltage Range(V) | 40-60 | 40-60 | |||||||
Max discharge current(A) | 135 | 190 | 220 | 250 | 120 | 160 | 200 | 240 | |
AC&Generator | Input voltage | Single phase 220/230 Vac | Three phase 220/230/380/400 Vac | ||||||
Frequency | 50-60Hz | 50-60Hz | |||||||
Rated Current(A) | 27.3 | 36.4 | 45.5 | 54.6 | 9.1 | 12.1 | 15.2 | 18.2 | |
Max Current(A) | 30 | 40 | 50 | 60 | 10 | 13.4 | 16.7 | 20 | |
Output | |||||||||
AC output | Rated capacity | 6kW | 8kW | 10kW | 12kW | 6kW | 8kW | 10kW | 12kW |
Max capaicty | 6.6kW | 8.8kW | 11kW | 13.2kW | 6.6kW | 8.8kW | 11kW | 13.2kW | |
Output voltage | Single phase 220/230 Vac | Three phase 220/230/380/400 Vac | |||||||
Frequency | 50/60Hz | 50/60Hz | |||||||
Rated Current(A) | 26.1 | 34.8 | 43.5 | 52.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
Power factor | 0.8 | ||||||||
Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | |
Transfer time(AC to DC) | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | |
Transfer time(DC to AC) | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms | |
Output voltage regulation | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | 10%rms | |
Bypass Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Saver Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
On grid Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | |
Efficiency | >95% | >95% | >95% | >95% | >95% | >95% | >95% | >95% | |
DC output UPS mode | Charging Strategy for Li Battery | Self-adaption to BMS | Self-adaption to BMS | ||||||
Max charging current | 135 | 190 | 220 | 250 | 120 | 160 | 200 | 240 | |
GENERAL | |||||||||
Display | LCD display | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC | Input AC,Output AC |
Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | Battery DC,Output Load | ||
Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | Alarm,Fault | ||
Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | Battery Charge Level | ||
Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | Output Frequency | ||
LED Indicator status | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | AC Line In:Green | |
Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | Inverter:Yellow | ||
Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | Charging:Yellow | ||
Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | Alarm:Red | ||
Interface | Communication | CAN | CAN | ||||||
Parallel | Max support 10pcs | Max support 10pcs | |||||||
Wifi | External | External | |||||||
Dry contact | For generator input | For generator input | |||||||
Environment | IP grade | IP65 | IP65 | ||||||
Temperature | -25~60℃ | -25~60℃ | |||||||
Cooling | Smart Cooling | Smart Cooling | |||||||
Accoustic Noise(db) | <55dB | <55dB | |||||||
Mechanical | Size | 346*506*255mm | 426*526*255mm | 446*576*254mm | 446*576*254mm | 446*576*254mm | |||
Carton dimension | 530*600*300mm | 530*600*300mm | 630*900*380mm | 630*900*380mm | 630*900*380mm | ||||
Net Weight | 24KG | 29KG | 31KG | 32KG | 37KG | 39KG | 41KG | 42KG | |
Gross weigth | 28KG | 34KG | 36KG | 37KG | 42KG | 45KG | 48KG | 50KG |