TK Series 2K-6K
NASN POWER
TK Series 2K-6K
30A
6KW
80A
>90%
Availability: | |
---|---|
TK series 2K - 6K (x for number 2 - 6) | ||||
Model | 2K | 3K | 5K -6K | |
Power rating | 2KW | 3KW | 5KW -6KW | |
Cell | cell voltage | 24VDC/48VDC | 48VDC | |
Overdischarge protection voltage | 21VDC / 42VDC (by default) | 42V DC ( Default) | ||
Battery type | Lead-acid or LiFePo4 | |||
Municipal electricity input | Phase position | monophase +G | ||
Input voltage | AC 220V/230V ±5% | |||
frequency | 50Hz /60Hz±5% | |||
Umains charge current | 10A -30A(MAX) | |||
MPPT controller | Enter the number of photovoltaic panels | 1 | ||
input voltage range | DC36-180V/ DC60-180V | DC 60-180V | ||
Recommended operating voltage | 108Vdc | 108Vdc | 108Vdc | |
Maximum open -circuit voltage | 180Vdc | 180Vdc | 180Vdc | |
rated current | 40A/60A/80A | |||
Generalized voltage | 14.2V/12V;28.4V/24V;56.8V/48V | |||
Constant charge voltage | 14V/12V;28V/24V;56V/48V | |||
Floating charge voltage | 13.5V/12V;27V/24V;54V/48V | |||
productive ness | ≥96.5% | |||
Inverse output | The AC output voltage | 220VAC; + 5% (inversion mode) | ||
Output frequency | 50 / 60 HZ + 1% (inversion mode) | |||
discharge waveform | pure sine wave | |||
Inversion efficiency | >90% | |||
Overload capacity | 101%-120%/30s:>125%300ms: | |||
Defencive function | Battery overvoltage protection, battery undervoltage protection, overload protection, short circuit protection,overtemperature protection, etc. | |||
Switching period | 0-5ms | |||
Isolation method | Power frequency transformer | |||
Complete performance | Working temperature | 0-40℃ | ||
Storage temperature | -15 ~ +50℃ | |||
Relative humidity | 0-90% (no condensation) |
TK series 2K - 6K (x for number 2 - 6) | ||||
Model | 2K | 3K | 5K -6K | |
Power rating | 2KW | 3KW | 5KW -6KW | |
Cell | cell voltage | 24VDC/48VDC | 48VDC | |
Overdischarge protection voltage | 21VDC / 42VDC (by default) | 42V DC ( Default) | ||
Battery type | Lead-acid or LiFePo4 | |||
Municipal electricity input | Phase position | monophase +G | ||
Input voltage | AC 220V/230V ±5% | |||
frequency | 50Hz /60Hz±5% | |||
Umains charge current | 10A -30A(MAX) | |||
MPPT controller | Enter the number of photovoltaic panels | 1 | ||
input voltage range | DC36-180V/ DC60-180V | DC 60-180V | ||
Recommended operating voltage | 108Vdc | 108Vdc | 108Vdc | |
Maximum open -circuit voltage | 180Vdc | 180Vdc | 180Vdc | |
rated current | 40A/60A/80A | |||
Generalized voltage | 14.2V/12V;28.4V/24V;56.8V/48V | |||
Constant charge voltage | 14V/12V;28V/24V;56V/48V | |||
Floating charge voltage | 13.5V/12V;27V/24V;54V/48V | |||
productive ness | ≥96.5% | |||
Inverse output | The AC output voltage | 220VAC; + 5% (inversion mode) | ||
Output frequency | 50 / 60 HZ + 1% (inversion mode) | |||
discharge waveform | pure sine wave | |||
Inversion efficiency | >90% | |||
Overload capacity | 101%-120%/30s:>125%300ms: | |||
Defencive function | Battery overvoltage protection, battery undervoltage protection, overload protection, short circuit protection,overtemperature protection, etc. | |||
Switching period | 0-5ms | |||
Isolation method | Power frequency transformer | |||
Complete performance | Working temperature | 0-40℃ | ||
Storage temperature | -15 ~ +50℃ | |||
Relative humidity | 0-90% (no condensation) |