Tell : 0086 135 1058 5626            E-mail :  info@nasn.cn

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

T4850M DC-DC MPPT charger module

T4850M is Low voltage photovoltaic  communication module.
  • T4850M

  • NASN

Availability:

T4850M is Low voltage photovoltaic  communication module.  It can extract maximum power in real time from the solar panels throughout the day. Module can work in outstanding reliability,efficiency and power density. It is specially designed for telecom, network access and data center applications.

1. Electrical Specification

1.1 DC Input Characteristics      

Parameters

Range

Note

Input Rated Voltage

100Vdc


Input operating voltage range

58Vdc to 150Vdc

Start-up voltage >75Vdc

MPPT Operating Voltage Range

58Vdc to 120Vdc

Voc not greater than 150V

Maximum Input Voltage

165Vdc

Modules are not damaged

 1.2 Input current

 

Rating

Maximum Values

Note

28.5A

Values 46A

Output rated voltage full load

 1.3 Conversion efficiency 

Parameters

Requirements

Note

Maximum efficiency

≥97%

100Vdc@ 25℃, 10 minutes power on After

 1.4 MPPT Efficiency

 

Parameters

Requirements

Note

MPPT efficiency

≥99.9%

Input power ≥ 400W

 1.5 Standby power consumption

 

Parameters

Requirements

Note

Standby power consumption

≤4W (no power consumption at night)

100Vdc Input

 1.6 Output external characteristics 

Output Voltage

Maximum Output Current

38~58V

Constant current 52A

 hybrid MPPT power

1.7 Output Voltage Adjustment Ratio

Output Voltage Index

Output Voltage

Accuracy Range

Note

source effect

43.2~58 V

≤±0.1%

Difference between DC output voltage and output voltage setting value at different input voltages

load effect

43.2~58 V

≤±0.5%

Difference between DC output voltage and output voltage setting value under different loads

Voltage stabilization accuracy

43.2~58 V

≤±0.6%

Difference between DC output voltage and output voltage setting value for different input voltages and different load combinations

Temperature coefficient (1/°C)

43.2~58 V

≤±0.02%

Difference between DC output voltage and output voltage setting value for every 1°C change in temperature relative to 25°C ambient temperature.

 Note: The set value refers to the rated 100Vdc input, corresponding to the output voltage tested at half load.

 1.8 Output Ripple and Noise

 

Output Voltage

Ripple And Noise (peak-to-peak)

Note

+43.2~58Vdc

≤200mVp-p

1. Rated input voltage range, minimum load to maximum load, full temperature range.

2. The oscilloscope bandwidth is set at 20 megahertz, and a 10 uf tantalum capacitor and a 0.1 uf ceramic chip capacitor are connected in parallel at the test point.

3. The test point is close to the power supply output.

 1.9 Output Load Dynamic Response 

1.9.1 Output Dynamic Load Response

 

Output Voltage

Overshooting Range

Note

Recovery Time

+43.2~58Vdc

±5%

Load 25%~50%;

50%~75%

Load shifts lope 0.1A/us

Load jump frequency 50Hz~1kHz

200us

 

 1.9.2 Output large dynamic response

 

Output Voltage

Overshooting Range

Note

+43.2~58Vdc

≤200mVp-p

Load 0% to 100%;

100%~0%

 Note: The above specifications are satisfied at DC source input. 

1.10 Output switching overshoot

 

Output Voltage

Overshoot Range

Note

+54.5V

<1 %

Rated input voltage range;

Minimum load ~ Maximum load.

 2. Mechanical

T4850M outlook

Previous: 
Next: 

ABOUT NASN

GUANGZHOU NASN POWER CO.,LTD is a professional EV charger, DC power supply and battery storage solution provider and enterprise in China, a wholly owned subsidy of NASN ELECTRONICS (HONGKONG) CO., LIMITED.

QUICK LINKS

PRODUCT CATEGORY

CONTACT US

   Contact person : Florence
   Tell : +86-20-86857678
    Phone : +86-135 1058 5626
    QQ : 28243245
    E-mail : info@nasn.cn
Copyright ©️ 2022 GUANGZHOU NASN POWER CO., LTD.  Technology by LeadongPrivacy Policy. Sitemap.