An Online UPS output is independent of voltage and frequency variations of the mains.
Offers the highest level of critical load protection as the load is supplied with closely regulated power at all times
Has a load break of less than 5ms when transferring between inverter and bypass
Is totally transparent to the load in the case of a mains failure
Is the most expensive capital cost of UPS systems
Has a higher running cost than other types of system, as the rectifier and inverter are permanently on load.
Parameters:
MODEL | UP-6KS |
Phase | Single phase |
Parallel funtion | support parallel |
Rated power | 6KVA, 5.1kW |
Input | |
Rated voltage & Frequency | 220Vac ; 40Hz~55Hz@50Hz system |
Voltage range | 176~270Vac |
Charing mode | |
DC input voltage & range | 48Vdc ; 40Vdc~66Vdc |
Battery type | Lithium battery,lead acid battery,colloidal battery |
Charging current | Defualt:10A, max 60A |
Bulk charging voltage | 58.4Vdc(Flooded battery) |
56.4Vdc(AGM/Gel battery) | |
Floating charging Voltage | 54Vdc |
Charging protection | 66Vdc |
Outputput | |
Output Voltage Waveform | Pure Sine Wave |
Output voltage | 220Vac |
Output frequency | 50Hz/60Hz |
Load regulation | <3% |
Frequency accuracy | <0.1% |
Power factor | >0.98 |
Parallel uneven flow | <3% rated current RMS |
No load power sonsumptic | <67W@48V |
Overload Protection | 5s@≥150% load; 10s@105%~150% load |
Surge capacity | 2* rated power for 5 seconds |
Inversion Efficiency | ≥93%(90% linear load) |
Transfer time (AC main to DC) | 0ms |
Transfer time (Bypass switch time) | 4ms |
Working Enviroment | |
Dielectric strength | 2000Vac/10mA/60s |
Humidity | 5%~95%, no moisture condensation |
Storage temperature | -20℃~+50℃ |
Noise(1m) | <45dB |
Communication | RS232 and USB |
Mechanical | |
Dimension (D*W*H), mm | 420 x 438 x 130.8 |
Net Weight(kg) | 15 |
Features: | ||||||||||||
1. Inbuilt charging function for battery; 2. Zero transfer time from line mode to battery model; 3.RS232 and USB communication port, optional SNMP remote; 4.Support parallel connection(max 9pcs) suitable for network cabinet power supply; 5.Auto restart while AC is recovering; 6.Cold start function 7.Zero-transfer Time 8.Smart battery charger design for optimized battery performance | ||||||||||||
1. LCD display
2. Bypass indicator
3. Status indicator
4. Charging indicator
5. Fault indicator
6. Function keys (Please refer to operation chapter for the detailed operation)
7. AC input terminals
8. AC output terminals
9. Grounding terminal
10. Battery input
11. Circuit breaker
12. RS-232 communication port
13. USB communication port
14. EPO port (Emergency power off)
15. Parallel communication port (only for parallel model)
16. Current sharing port (only for parallel model)
17. Intelligent slot
An Online UPS output is independent of voltage and frequency variations of the mains.
Offers the highest level of critical load protection as the load is supplied with closely regulated power at all times
Has a load break of less than 5ms when transferring between inverter and bypass
Is totally transparent to the load in the case of a mains failure
Is the most expensive capital cost of UPS systems
Has a higher running cost than other types of system, as the rectifier and inverter are permanently on load.
Parameters:
MODEL | UP-6KS |
Phase | Single phase |
Parallel funtion | support parallel |
Rated power | 6KVA, 5.1kW |
Input | |
Rated voltage & Frequency | 220Vac ; 40Hz~55Hz@50Hz system |
Voltage range | 176~270Vac |
Charing mode | |
DC input voltage & range | 48Vdc ; 40Vdc~66Vdc |
Battery type | Lithium battery,lead acid battery,colloidal battery |
Charging current | Defualt:10A, max 60A |
Bulk charging voltage | 58.4Vdc(Flooded battery) |
56.4Vdc(AGM/Gel battery) | |
Floating charging Voltage | 54Vdc |
Charging protection | 66Vdc |
Outputput | |
Output Voltage Waveform | Pure Sine Wave |
Output voltage | 220Vac |
Output frequency | 50Hz/60Hz |
Load regulation | <3% |
Frequency accuracy | <0.1% |
Power factor | >0.98 |
Parallel uneven flow | <3% rated current RMS |
No load power sonsumptic | <67W@48V |
Overload Protection | 5s@≥150% load; 10s@105%~150% load |
Surge capacity | 2* rated power for 5 seconds |
Inversion Efficiency | ≥93%(90% linear load) |
Transfer time (AC main to DC) | 0ms |
Transfer time (Bypass switch time) | 4ms |
Working Enviroment | |
Dielectric strength | 2000Vac/10mA/60s |
Humidity | 5%~95%, no moisture condensation |
Storage temperature | -20℃~+50℃ |
Noise(1m) | <45dB |
Communication | RS232 and USB |
Mechanical | |
Dimension (D*W*H), mm | 420 x 438 x 130.8 |
Net Weight(kg) | 15 |
Features: | ||||||||||||
1. Inbuilt charging function for battery; 2. Zero transfer time from line mode to battery model; 3.RS232 and USB communication port, optional SNMP remote; 4.Support parallel connection(max 9pcs) suitable for network cabinet power supply; 5.Auto restart while AC is recovering; 6.Cold start function 7.Zero-transfer Time 8.Smart battery charger design for optimized battery performance | ||||||||||||
1. LCD display
2. Bypass indicator
3. Status indicator
4. Charging indicator
5. Fault indicator
6. Function keys (Please refer to operation chapter for the detailed operation)
7. AC input terminals
8. AC output terminals
9. Grounding terminal
10. Battery input
11. Circuit breaker
12. RS-232 communication port
13. USB communication port
14. EPO port (Emergency power off)
15. Parallel communication port (only for parallel model)
16. Current sharing port (only for parallel model)
17. Intelligent slot