NASN
NASN
8504
75VDC
750Vdc
99%
5m
54
Availability: | |
---|---|
This Container Battery energy storage systems (CBESS) can be used for a variety of applications, including frequency regulation, demand response, transmission and distribution infrastructure deferral, integration of renewable energy, and micro-grids. Different battery technologies can enable different applications that can provide various benefits to utility services, Independent System Operator (ISO) services, Regional Transmission Organization (RTO) services, and consumer services.with battery pack built-in, can charge ev at any time and any place. Mobile ev charger system, can be installed on ev self-contained VAN, or a towed trailer to provide roadside or remote electric vehicle rescue when the battery runs out, and on-demanding charign to door service. This emergency mobile ev charging system on the vehicle breaks space limitations and allows rapid deployment without infrastructure. |
This Container Battery energy storage systems (CBESS) can be used for a variety of applications, including frequency regulation, demand response, transmission and distribution infrastructure deferral, integration of renewable energy, and micro-grids. Different battery technologies can enable different applications that can provide various benefits to utility services, Independent System Operator (ISO) services, Regional Transmission Organization (RTO) services, and consumer services.with battery pack built-in, can charge ev at any time and any place. Mobile ev charger system, can be installed on ev self-contained VAN, or a towed trailer to provide roadside or remote electric vehicle rescue when the battery runs out, and on-demanding charign to door service. This emergency mobile ev charging system on the vehicle breaks space limitations and allows rapid deployment without infrastructure. |
EV Charger | Output Voltage | 200-750Vdc | |
Output power | Min 120KW | ||
Charger communication protocol | IEC 61851-24; DIN70121;ISO15118 | ||
Charger plug number | 1 to 3 | ||
Charger plug standard | CHAdeMO CCS, GB/T, AC for option | ||
support charge 2 evs at same time | YES | ||
Recharge Battery | AC Gird | 3phase 400Vac±15% (3P+N+PE) | |
DC CCS public charger | CCS input | ||
DC CHAdeMo public charger | CHAdeMO input | ||
AC public charger | Type 1 or Type 2 input for option | ||
Battery system | Battery Capacity (KWH) | 100KWH | |
Cell Chemistry | Lithium iron phosphate LiFeP04 | ||
DOD% (Depth of discharge) | 90% | ||
Working Temperate | Charge | - 20 ℃ to 55 ℃ | |
Discharge | - 20 ℃ to 65 ℃ | ||
Communication Protocol | RS485/CAN/LAN | ||
Cycle Life (0.3C) | > 6000 TIMES, 100% DOD @25℃ | ||
Structure Design | Charge&Discharge at same time | YES | |
Installation method | Floor Mounted or Movable | ||
Cable Length | 5m length for each | ||
LED indicator | 3 LED indicator light or Light Strip | ||
LCD screen | EV Charger status screen | ||
5inch battery status screen | |||
Emergency Button | YES | ||
Communication | EN-GATE v.s. Charger | CAN 2.0 (CHAdeMO, GB/T) | |
PLC (CCS) | |||
EN-GATE v.s. Backend | Ethernet/WIFI/3G/4G for option | ||
Charger Communication protocol | OCPP1.6 (JSON) |
EV Charger | Output Voltage | 200-750Vdc | |
Output power | Min 120KW | ||
Charger communication protocol | IEC 61851-24; DIN70121;ISO15118 | ||
Charger plug number | 1 to 3 | ||
Charger plug standard | CHAdeMO CCS, GB/T, AC for option | ||
support charge 2 evs at same time | YES | ||
Recharge Battery | AC Gird | 3phase 400Vac±15% (3P+N+PE) | |
DC CCS public charger | CCS input | ||
DC CHAdeMo public charger | CHAdeMO input | ||
AC public charger | Type 1 or Type 2 input for option | ||
Battery system | Battery Capacity (KWH) | 100KWH | |
Cell Chemistry | Lithium iron phosphate LiFeP04 | ||
DOD% (Depth of discharge) | 90% | ||
Working Temperate | Charge | - 20 ℃ to 55 ℃ | |
Discharge | - 20 ℃ to 65 ℃ | ||
Communication Protocol | RS485/CAN/LAN | ||
Cycle Life (0.3C) | > 6000 TIMES, 100% DOD @25℃ | ||
Structure Design | Charge&Discharge at same time | YES | |
Installation method | Floor Mounted or Movable | ||
Cable Length | 5m length for each | ||
LED indicator | 3 LED indicator light or Light Strip | ||
LCD screen | EV Charger status screen | ||
5inch battery status screen | |||
Emergency Button | YES | ||
Communication | EN-GATE v.s. Charger | CAN 2.0 (CHAdeMO, GB/T) | |
PLC (CCS) | |||
EN-GATE v.s. Backend | Ethernet/WIFI/3G/4G for option | ||
Charger Communication protocol | OCPP1.6 (JSON) |