Lithium Online High Frequency rack UPS

  • 1~3kva

Availability:


Online UPS Summary

An Online UPS output is independent of voltage and frequency variations of the mains.

  • ·Zero transfer time,double conversion online UPS

  • ·3-level Inverter for the best loading capability

  • ·Wide input voltage range 90V~300V

  • ·DSP Digital Control Based ·Generator compatible

  • ·High Efficiency

  • ·Li-ion Battery Powered

  • ·Dry Contact control Interface for BMS

  • ·High input power factor >0.99 ·Reliable design,made with strong glass fiber base (FR4)double side PCB


    Model definition

    model definition

Parameters:


Model

HSS1101L

HSS1101LS

HSS1102L

HSS1102LS

HSS1103L

HSS1103LS

Capacity

VA/W

1kVA/900W

2kVA/1.8kW

3kVA/2.7kW

Topology

Double Conversion Online UPS

Phase

Single Phase Input Single Phase Output

Mains Input

Wiring

L/N+PE

Rated Voltage

208/220/230/240VAC

Voltage Range

90~300VAC

Frequency Range

40Hz-70Hz

Input Power Factor

≥0.99

AC Output

Wiring

L/N+PE

Output Voltage

208/220/230/240VAC

Voltage Regulation

±1%

Output Frequency

50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)

Waveform

Sine Wave

Distortion

(THDV%)

<2%(Linear Load)

<8%(None-Linear Load)

Over load capability

100%~105% continuous.

60Sec.@105%~130% Rated Load

10Sec.@130%~150% Rated Load

0.3Sec.@>150%Rated Load

Efficiency

Line Mode

90%

91%

92%

Battery Mode

87%

88%

89%

Battery

&

Charger

Rated Battery Voltage

48/51.2VDC (default for 15/16cell of LiFePO4 )

Battery Capacity

615WH

External Battery Depends

920WH

External Battery Depends

1250WH

External Battery Depends

Backup Time

>30mins @ Full Load

>20mins @ Full Load

>20mins @ Full Load

Backup Time 2

(External Battery Module)

51.2V30AH-90mins

51.2V50AH-150mins

51.2V100AH-300mins

@ Full Load

51.2V30AH-45mins

51.2V50AH-75mins

51.2V100AH-150mins

@ Full Load

51.2V30AH-30mins

51.2V50AH-50mins

51.2V100AH-100mins

@ Full Load

Charging Current

Standard Model with Internal Battery:4A

Long Backup Time Model :4A / 8A(Optional)/ 16A(Optional)

Charging Voltage

56.8V(default for 16cell of LiFePO4 ) / Customized according to battery request

Charger Behavior &

Protection

CC. CV. Floating. Turn-Off 4 states

3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface

Physical

Chassis Style

RACK  

Rack Dimension

1K: 438x88(2U)X400mm

1KS: 438x88(2U)X400mm

2K: 438x88(2U)X500mm

2KS:438x88(2U)X400mm

3K: 438x88(2U)X650mm

3KS:438x88(2U)X400mm

Tower Dimension

1KS~3KS: 190×318×368mm

  1K/2K/3K:190×323×420MM


Weight(Tower)

10.8kg

7.0kg

16.5kg

7.3kg

18.0kg

7.9kg

Weight(Rack)

12.5kg

6.5kg

21.6kg

6.8kg

24.5kg

8.2kg

HMI

LED DISPLAY

Mains / battery status, Load level, battery level, Operation Mode

LCD DISPLAY with LED indicator

Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status

Standards

COMMUNICATION

1. RS232 PORT/USB Card (not HID)

2. Dry Contact Interface for BMS control

3. ModBUS For BMS interface

Optional Extension Card

4. Network Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown

5. RS485-Modbus Card,  LAN(TCP IP)-ModBUS Card,

6. Mini AS400 Relay Card

Operating Environment

Endurance

Temperature range

-10~50oC

Relative Humidity

0-98%(Non-condensing)

Acoustics Noise

<55dB @ 1 meters


Model

LSS1101L

LSS1101LS

LSS1102L

LSS1102LS

LSS1103L

LSS1103LS

Capacity

VA/W

1kVA/900W

2kVA/1.8kW

3kVA/2.7kW

Topology

Double Conversion Online UPS

Phase

Single Phase Input Single Phase Output

Mains Input

Wiring

1 phase 3wires ( L / N+PE)

Rated Voltage

110/115/120/127VAC

Voltage Range

Line-Neutral: 60~145VAC

Frequency Range

40Hz~70Hz

Input Power Factor

≥0.99

AC Output

Wiring

L/N+PE

Output Voltage

110/115/120/127VAC

Voltage Regulation

±1%

Output Frequency

50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)

Waveform

Sine Wave

Distortion

(THDV%)

<2%(Linear Load)


<8%(None-Linear Load)

Over load capability

1Min@105%~125%Rated Load

30Sec.@125%~150%Rated Load

0.5Sec.@>150%Rated Load

Efficiency

AC/AC Mode

88%

89%

90%

DC/AC Mode

86%

87%

88%

Battery

&

Charger

Rated Battery Voltage

48/51.2VDC (default for 15/16cell of LiFePO4 )

Battery Capacity

615WH

External Battery Depends

920WH

External Battery Depends

1250WH

External Battery Depends

Backup Time

>30mins @ Full Load


>20mins @ Full Load


>20mins @ Full Load


Backup Time 2

(External Battery Module)

51.2V30AH-90mins

51.2V50AH-150mins

51.2V100AH-300mins

@ Full Load

51.2V30AH-45mins

51.2V50AH-75mins

51.2V100AH-150mins

@ Full Load

51.2V30AH-30mins

51.2V50AH-50mins

51.2V100AH-100mins

@ Full Load

Charging Current

Standard Model with Internal Battery:4A

Long Backup Time Model :4A / 8A(Optional)/ 16A(Optional)

Charging Voltage

56.5V(default for 16cell of LiFePO4 ) / Customized according to battery request

Charger Behavior &

Protection

CC. CV. Floating. Turn-Off 4 states

3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface

Physical

Chassis Style

RACK 

Rack Dimension

1K: 438x88(2U)X400mm

1KS: 438x88(2U)X400mm

2K: 438x88(2U)X500mm

2KS:438x88(2U)X400mm

3K: 438x88(2U)X650mm

3KS:438x88(2U)X400mm

Tower Dimension

1KS~3KS: 190×323×368MM

  1K~3K:190×323×420MM

Weight(Tower)

10.8kg

5.0kg

16.5kg

5.5kg

18.0kg

7.9kg

Weight(Rack)

12.5kg

6.5kg

21.6kg

6.8kg

24.5kg

8.2kg

HMI

LED DISPLAY

Mains / battery status, Load level, battery level, Operation Mode

LCD DISPLAY with LED indicator

Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status

Standards

COMMUNICATION

1. RS232 PORT/USB Card (not HID)

2. Dry Contact Interface for BMS control

3. ModBUS For BMS interface

Optional Extension Card

4. Network Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown

5. RS485-Modbus Card,  LAN(TCP IP)-ModBUS Card,

6. Mini AS400 Relay Card

Operating Environment

Endurance

Temperature range

-10~50oC

Relative Humidity

0-98%(Non-condensing)

Acoustics Noise

<55dB @ 1 meters



Features:

1. Inbuilt charging function for battery;

2. Zero transfer time from line mode to battery model;

3.RS232 and USB communication port;

4.Support parallel connectionmax 9pcs) suitable for network cabinet power supply;

5.Auto restart while AC is recovering;

6.Cold start function

7.Zero-transfer Time

8.Smart battery charger design for optimized battery performance





 

front panel

back panel














Previous: 
Next: 

ABOUT NASN

GUANGZHOU NASN POWER CO.,LTD is a professional EV charger, DC power supply and battery storage solution provider and enterprise in China, a wholly owned subsidy of NASN ELECTRONICS (HONGKONG) CO., LIMITED.

QUICK LINKS

PRODUCT CATEGORY

CONTACT US

   Contact person : Florence
   Tell : +86-20-86857678
    Phone : +86-135 1058 5626
    QQ : 28243245
    E-mail : info@nasn.cn
Copyright ©️ 2022 GUANGZHOU NASN POWER CO., LTD.  Technology by LeadongPrivacy Policy. Sitemap.