SH48V5KW220
NASN POWER
5kW
80%
Single phase 220/230 Vac
Availability: | |
---|---|
Pure sine wave inverter
Inverter running without battery
Built-in MPPT solar controller
Configurable input voltage range for home appliances and personal computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar Charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/ Over temperature/ short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
Installation
CAUTION: For safety operation and regulation compliance, it’s requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it’s still requested to have over-current protection installed.
AC Input/Output Connection
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
INVERTER MODEL | 5KW |
Input Voltage Waveform | Sinusoidal (utility or generator) |
Nominal Input Voltage | 230Vac |
Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
High Loss Voltage | 280Vac±7V |
High Loss Return Voltage | 270Vac±7V |
Max AC Input Voltage | 300Vac |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
Low Loss Frequency | 40±1Hz |
Low Loss Return Frequency | 42±1Hz |
High Loss Frequency | 65±1Hz |
High Loss Return Frequency | 63±1Hz |
Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) |
Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
Output power derating: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated. |
|
INVERTER MODEL | 5KW |
Rated Output Power | 5KW |
Output Voltage Waveform | Pure Sine Wave |
Output Voltage Regulation | 230Vac±5% |
Output Frequency | 60Hz or 50Hz |
Peak Efficiency | 94% |
Overload Protection | 5s@≥150% load;10s@110%~150% load |
Surge Capacity | 2* rated power for 5 seconds |
Nominal DC Input Voltage | 48Vdc |
Cold Start Voltage | 46.0Vdc |
Low DC Warning Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 44.0Vdc 42.8Vdc 40.4Vdc |
Low DC Warning Return Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 46.0Vdc 44.8Vdc 42.4Vdc |
Low DC Cut-off Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 42.0Vdc 40.8Vdc 38.4Vdc |
Utility Charging Mode | ||
INVERTER MODEL | 5KW | |
Max Charging Current (PV+AC) | 100Amp (@ VI/P=230Vac) | |
Max Charging Current (AC) | 60Amp (@ VI/P=230Vac) | |
Bulk Charging Voltage | Flooded Battery | 58.4Vdc |
AGM / Gel Battery | 56.4Vdc | |
Floating Charging Voltage | 54Vdc | |
Overcharge Protection | 63Vdc | |
Charging Algorithm | 3-Step | |
Charging Curve | ||
Solar Input | ||
INVERTER MODEL | 5KW | |
Rated Power | 5500W | |
Max. PV Array Open Circuit Voltage | 500Vdc | |
PV Array MPPT Voltage Range | 120Vdc~450Vdc | |
Max. Input Current | 18A | |
Max.Charging Current(PV) | 100A |
INVERTER MODEL | 5KW |
Safety Certification | CE |
Operating Temperature Range | -10°C to 55°C |
Storage temperature | -15°C~ 60°C |
Humidity | 5% to 95% Relative Humidity (Non-condensing) |
Dimension (D*W*H), mm | 438x438x130.8 |
Net Weight, kg | 14 |
Parallel Operation in Single phase
Max 12 units can be paralleled in single phase connection.
Support 3-phase equipment
Max 4 units in each phase can be paralleled in three phase connection. Total 12 units.
Pure sine wave inverter
Inverter running without battery
Built-in MPPT solar controller
Configurable input voltage range for home appliances and personal computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar Charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/ Over temperature/ short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
Installation
CAUTION: For safety operation and regulation compliance, it’s requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it’s still requested to have over-current protection installed.
AC Input/Output Connection
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
INVERTER MODEL | 5KW |
Input Voltage Waveform | Sinusoidal (utility or generator) |
Nominal Input Voltage | 230Vac |
Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
High Loss Voltage | 280Vac±7V |
High Loss Return Voltage | 270Vac±7V |
Max AC Input Voltage | 300Vac |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
Low Loss Frequency | 40±1Hz |
Low Loss Return Frequency | 42±1Hz |
High Loss Frequency | 65±1Hz |
High Loss Return Frequency | 63±1Hz |
Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) |
Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
Output power derating: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated. |
|
INVERTER MODEL | 5KW |
Rated Output Power | 5KW |
Output Voltage Waveform | Pure Sine Wave |
Output Voltage Regulation | 230Vac±5% |
Output Frequency | 60Hz or 50Hz |
Peak Efficiency | 94% |
Overload Protection | 5s@≥150% load;10s@110%~150% load |
Surge Capacity | 2* rated power for 5 seconds |
Nominal DC Input Voltage | 48Vdc |
Cold Start Voltage | 46.0Vdc |
Low DC Warning Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 44.0Vdc 42.8Vdc 40.4Vdc |
Low DC Warning Return Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 46.0Vdc 44.8Vdc 42.4Vdc |
Low DC Cut-off Voltage @ load < 20% @ 20% ≤ load < 50% @ load ≥ 50% | 42.0Vdc 40.8Vdc 38.4Vdc |
Utility Charging Mode | ||
INVERTER MODEL | 5KW | |
Max Charging Current (PV+AC) | 100Amp (@ VI/P=230Vac) | |
Max Charging Current (AC) | 60Amp (@ VI/P=230Vac) | |
Bulk Charging Voltage | Flooded Battery | 58.4Vdc |
AGM / Gel Battery | 56.4Vdc | |
Floating Charging Voltage | 54Vdc | |
Overcharge Protection | 63Vdc | |
Charging Algorithm | 3-Step | |
Charging Curve | ||
Solar Input | ||
INVERTER MODEL | 5KW | |
Rated Power | 5500W | |
Max. PV Array Open Circuit Voltage | 500Vdc | |
PV Array MPPT Voltage Range | 120Vdc~450Vdc | |
Max. Input Current | 18A | |
Max.Charging Current(PV) | 100A |
INVERTER MODEL | 5KW |
Safety Certification | CE |
Operating Temperature Range | -10°C to 55°C |
Storage temperature | -15°C~ 60°C |
Humidity | 5% to 95% Relative Humidity (Non-condensing) |
Dimension (D*W*H), mm | 438x438x130.8 |
Net Weight, kg | 14 |
Parallel Operation in Single phase
Max 12 units can be paralleled in single phase connection.
Support 3-phase equipment
Max 4 units in each phase can be paralleled in three phase connection. Total 12 units.