The LCD rackmount Power Supply Pure Sine Wave Inverter from Communication Power Inverter NASN Factory is a new generation of intelligent MCU high frequency Power Supply inverter and a standalone DC to AC inverter system for Telecom and industrial power applications. Developed and designed for the requirements of Telecom and Industrial, heavy duty application, which delivers continues true sine wave output power with high stability.Comprehensive solutions for servers, cloud computing, edge computing, 5G networks and communications infrastructure.Widely applied in communication Power systems, railway power systems, and other power systems to meet the high quality and high reliability requirements, and applicable to all the uninterrupted sine wave AC output systems that are sensitive to power interference and require reliable and clean.In addition, the inverter system offers new opportunities for energy savings by providing backup AC power.DC / AC inverters for telecommunication and communication equipment convert the DC batteries voltage to AC. NASN’s Inverters are designed and built for reliability. These telecom-grade inverters provide pure ac sine-wave power for all critical network needs. we offer a wide range of inverters and converters in different capacities to integrate with DC Power Systems.
MODEL | T48/220-XKS | |||||||||
Technical Index(VA) | 0.5K | 1K | 2K | 3K | 4K | 5K | 6K | 8K | 10K | |
DC input | Rated input voltage (Vdc) | 48Vdc | ||||||||
Rated input current (A) | 11 | 21 | 42 | 63 | 83 | 104 | 125 | 167 | 208 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 40V--60V Startup voltage 45.5V—57V | |||||||||
Backward noise current | ≤10% | |||||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 260V-180V(±10V) | ||||||||
Rated input current (A) | 2.3 | 4.5 | 9.1 | 13.6 | 18.2 | 22.7 | 27.2 | 36.3 | 45.4 | |
By-pass conversion time (ms) | ≤5ms | |||||||||
AC output | Rated capacity (VA) | 500 | 1K | 2K | 3K | 4K | 5K | 6K | 8K | 10K |
Rated output power (W) | 400 | 800 | 1600 | 2400 | 3200 | 4000 | 4800 | 6400 | 8000 | |
Inverter output voltage and frequency | 220Vac,50HZ/60HZ | |||||||||
Inverter output current (A) | 1.8 | 3.6 | 7.3 | 11 | 14.5 | 18.2 | 21.8 | 29 | 36.3 | |
Output voltage precision (V) | 220±1.5% | |||||||||
Output frequency precision (Hz) | 50±0.1% Or 60±0.1% | |||||||||
Waveform | Pure sine wave | |||||||||
Total harmonic distortion (THD) | ≤3% (linear load) | |||||||||
Dynamic response time | 5% (load 0←→100%) | |||||||||
Power factor (PF) | 0.8 | |||||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | |||||||||
Inversion efficiency (80% resistive load) | ≥85% | |||||||||
By-pass conversion time (ms) | ≤5ms | |||||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | ||||||||
Noise (1m) | ≤40dB | |||||||||
Operating environment temperature | -20℃~+50℃ | |||||||||
Humidity | 0~90%, no moisture condensation | |||||||||
Operating altitude (m) | ≤2000 | |||||||||
Communication | RS232 and RS485, SNMP optional | |||||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |||||||||
Mechanical size | Standard rack | 347*482*88 | 430*482*88 | 436*482*176 | ||||||
(Depth × Width × Height) (mm) | ||||||||||
Protection function | DC input reverse polarity protection | Available | N/A | |||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |
MODEL | T48/120-XKS | |||||||
Technical Index(VA) | 0.5K | 1K | 2K | 3K | 4K | 5K | 6K | |
DC input | Rated input voltage (Vdc) | 48Vdc | ||||||
Rated input current (A) | 11 | 21 | 42 | 63 | 83 | 104 | 125 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 40V--60V Startup voltage 45.5V—57V | |||||||
Backward noise current | ≤10% | |||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 132V-90V(±10V) | ||||||
Rated input current (A) | 4.2 | 8.3 | 16.7 | 26 | 33.3 | 41.6 | 50 | |
By-pass conversion time (ms) | ≤5ms | |||||||
AC output | Rated capacity (VA) | 500 | 1K | 2K | 3K | 4K | 5K | 6K |
Rated output power (W) | 400 | 800 | 1600 | 2400 | 3200 | 4000 | 4800 | |
Inverter output voltage and frequency | 120Vac,60HZ | |||||||
Inverter output current (A) | 3.3 | 6.7 | 13.3 | 20 | 27 | 33.3 | 40 | |
Output voltage precision (V) | 120±1.5% | |||||||
Output frequency precision (Hz) | 60±0.1% | |||||||
Waveform | Pure sine wave | |||||||
Total harmonic distortion (THD) | ≤3% (linear load) | |||||||
Dynamic response time | 5% (load 0←→100%) | |||||||
Power factor (PF) | 0.8 | |||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | |||||||
Inversion efficiency (80% resistive load) | ≥85% | |||||||
By-pass conversion time (ms) | ≤5ms | |||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | ||||||
Noise (1m) | ≤40dB | |||||||
Operating environment temperature | -20℃~+50℃ | |||||||
Humidity | 0~90%, no moisture condensation | |||||||
Operating altitude (m) | ≤2000 | |||||||
Communication | RS232 and RS485, SNMP optional | |||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |||||||
Mechanical size(mm) | Standard rack | 347*482*88 | 430*482*88 | |||||
(Depth * Width *Height) | ||||||||
Protection function | DC input reverse polarity protection | Available | ||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |
Features: Continuous duty rated full output wattage maintained even during extended power outages; Low EMI and RFI interference characteristics; User-friendly Status and Diagnostic LCD/LED displays,easy to operate; Utility bypass function with fast load transfer switch; Remote Power Management optional via RS-232 port; Optional SNMP card; Comprehensive circuit and load protections over-current, over- temp, overload, reverse polarity, over voltage, low voltage voltage; Optional three working modes: AC mains first, DC inverter first, pure DC inverter; Form C alarm contacts for monitoring AC Fault and DC Abnormal conditions; Optional three working modes: AC mains first, DC inverter first, pure DC inverter Install: 19 or 23 inch rack or standalone | |||||||||||||||||
Application: | |||||||||||||||||
Applied to Inductive Load and Resistive Load | |||||||||||||||||
Telecom / Utility Power Supply System:Power station,Airconditioner,Data management equiment and system,office,Server; | |||||||||||||||||
Vehicle and shipboard equipment: Railway station, transportation equipment, etc. Industrial equipment: solar power, wind power, gas discharge lamps, etc. Office equipment: computer, printer, copy, scanner, etc. Kitchen appliances: microwave oven, induction cooker, rice cooker, etc. Household electrical equipment: electric fans, vacuum cleaners, lighting fixtures, etc. | |||||||||||||||||
The LCD rackmount Power Supply Pure Sine Wave Inverter from Communication Power Inverter NASN Factory is a new generation of intelligent MCU high frequency Power Supply inverter and a standalone DC to AC inverter system for Telecom and industrial power applications. Developed and designed for the requirements of Telecom and Industrial, heavy duty application, which delivers continues true sine wave output power with high stability.Comprehensive solutions for servers, cloud computing, edge computing, 5G networks and communications infrastructure.Widely applied in communication Power systems, railway power systems, and other power systems to meet the high quality and high reliability requirements, and applicable to all the uninterrupted sine wave AC output systems that are sensitive to power interference and require reliable and clean.In addition, the inverter system offers new opportunities for energy savings by providing backup AC power.DC / AC inverters for telecommunication and communication equipment convert the DC batteries voltage to AC. NASN’s Inverters are designed and built for reliability. These telecom-grade inverters provide pure ac sine-wave power for all critical network needs. we offer a wide range of inverters and converters in different capacities to integrate with DC Power Systems.
MODEL | T48/220-XKS | |||||||||
Technical Index(VA) | 0.5K | 1K | 2K | 3K | 4K | 5K | 6K | 8K | 10K | |
DC input | Rated input voltage (Vdc) | 48Vdc | ||||||||
Rated input current (A) | 11 | 21 | 42 | 63 | 83 | 104 | 125 | 167 | 208 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 40V--60V Startup voltage 45.5V—57V | |||||||||
Backward noise current | ≤10% | |||||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 260V-180V(±10V) | ||||||||
Rated input current (A) | 2.3 | 4.5 | 9.1 | 13.6 | 18.2 | 22.7 | 27.2 | 36.3 | 45.4 | |
By-pass conversion time (ms) | ≤5ms | |||||||||
AC output | Rated capacity (VA) | 500 | 1K | 2K | 3K | 4K | 5K | 6K | 8K | 10K |
Rated output power (W) | 400 | 800 | 1600 | 2400 | 3200 | 4000 | 4800 | 6400 | 8000 | |
Inverter output voltage and frequency | 220Vac,50HZ/60HZ | |||||||||
Inverter output current (A) | 1.8 | 3.6 | 7.3 | 11 | 14.5 | 18.2 | 21.8 | 29 | 36.3 | |
Output voltage precision (V) | 220±1.5% | |||||||||
Output frequency precision (Hz) | 50±0.1% Or 60±0.1% | |||||||||
Waveform | Pure sine wave | |||||||||
Total harmonic distortion (THD) | ≤3% (linear load) | |||||||||
Dynamic response time | 5% (load 0←→100%) | |||||||||
Power factor (PF) | 0.8 | |||||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | |||||||||
Inversion efficiency (80% resistive load) | ≥85% | |||||||||
By-pass conversion time (ms) | ≤5ms | |||||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | ||||||||
Noise (1m) | ≤40dB | |||||||||
Operating environment temperature | -20℃~+50℃ | |||||||||
Humidity | 0~90%, no moisture condensation | |||||||||
Operating altitude (m) | ≤2000 | |||||||||
Communication | RS232 and RS485, SNMP optional | |||||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |||||||||
Mechanical size | Standard rack | 347*482*88 | 430*482*88 | 436*482*176 | ||||||
(Depth × Width × Height) (mm) | ||||||||||
Protection function | DC input reverse polarity protection | Available | N/A | |||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |
MODEL | T48/120-XKS | |||||||
Technical Index(VA) | 0.5K | 1K | 2K | 3K | 4K | 5K | 6K | |
DC input | Rated input voltage (Vdc) | 48Vdc | ||||||
Rated input current (A) | 11 | 21 | 42 | 63 | 83 | 104 | 125 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 40V--60V Startup voltage 45.5V—57V | |||||||
Backward noise current | ≤10% | |||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 132V-90V(±10V) | ||||||
Rated input current (A) | 4.2 | 8.3 | 16.7 | 26 | 33.3 | 41.6 | 50 | |
By-pass conversion time (ms) | ≤5ms | |||||||
AC output | Rated capacity (VA) | 500 | 1K | 2K | 3K | 4K | 5K | 6K |
Rated output power (W) | 400 | 800 | 1600 | 2400 | 3200 | 4000 | 4800 | |
Inverter output voltage and frequency | 120Vac,60HZ | |||||||
Inverter output current (A) | 3.3 | 6.7 | 13.3 | 20 | 27 | 33.3 | 40 | |
Output voltage precision (V) | 120±1.5% | |||||||
Output frequency precision (Hz) | 60±0.1% | |||||||
Waveform | Pure sine wave | |||||||
Total harmonic distortion (THD) | ≤3% (linear load) | |||||||
Dynamic response time | 5% (load 0←→100%) | |||||||
Power factor (PF) | 0.8 | |||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | |||||||
Inversion efficiency (80% resistive load) | ≥85% | |||||||
By-pass conversion time (ms) | ≤5ms | |||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | ||||||
Noise (1m) | ≤40dB | |||||||
Operating environment temperature | -20℃~+50℃ | |||||||
Humidity | 0~90%, no moisture condensation | |||||||
Operating altitude (m) | ≤2000 | |||||||
Communication | RS232 and RS485, SNMP optional | |||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |||||||
Mechanical size(mm) | Standard rack | 347*482*88 | 430*482*88 | |||||
(Depth * Width *Height) | ||||||||
Protection function | DC input reverse polarity protection | Available | ||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |
Features: Continuous duty rated full output wattage maintained even during extended power outages; Low EMI and RFI interference characteristics; User-friendly Status and Diagnostic LCD/LED displays,easy to operate; Utility bypass function with fast load transfer switch; Remote Power Management optional via RS-232 port; Optional SNMP card; Comprehensive circuit and load protections over-current, over- temp, overload, reverse polarity, over voltage, low voltage voltage; Optional three working modes: AC mains first, DC inverter first, pure DC inverter; Form C alarm contacts for monitoring AC Fault and DC Abnormal conditions; Optional three working modes: AC mains first, DC inverter first, pure DC inverter Install: 19 or 23 inch rack or standalone | |||||||||||||||||
Application: | |||||||||||||||||
Applied to Inductive Load and Resistive Load | |||||||||||||||||
Telecom / Utility Power Supply System:Power station,Airconditioner,Data management equiment and system,office,Server; | |||||||||||||||||
Vehicle and shipboard equipment: Railway station, transportation equipment, etc. Industrial equipment: solar power, wind power, gas discharge lamps, etc. Office equipment: computer, printer, copy, scanner, etc. Kitchen appliances: microwave oven, induction cooker, rice cooker, etc. Household electrical equipment: electric fans, vacuum cleaners, lighting fixtures, etc. | |||||||||||||||||