Rectifiers modular 24Vdc/48Vdc/125Vdc is for the application of electrical substations to charge lead acid, Nickel Cadmio and LIFEP04 batteries.
Features:
1. Switch Mode Power Supply;
2. Hot swappable and Plug and Play;
3 .N+1 redundancy,each module available in 50A@48Vdc & 60A@24Vdc;
4 .AC /DC distribution system for AC input/ DC output distribution and protection;
5.RS232, RS485, SNMP communication for remote control;
6.Compact design and embedded modular system, support power system and module sleep, efficient mixing, energy saving;
7.High Efficiency with low EMI. CE Safety and EMC certification
8.Protection for Input and output over /under voltage,short circuit and over temperature
MODEL | A220/24-60M1 | A220/24-180M3 | A220/24-240M4 | A220/24-360M6 | |
Configuration | 1pcs 24V/60A module +1pcs monitor | 3pcs 24V/60A module +1pcs monitor | 4pcs 24V/60A module +1pcs monitor | 6pcs 24V/60A module +1pcs monitor | |
Environmental | Operating temperature | -40°C ~ 55°C | |||
Storage temperature | -40°C ~ 70°C | ||||
Relative humidity | 5%~95%RH(40±2℃,no condensation) | ||||
Atmospheric pressure | 62kPa~106kPa | ||||
Altitude | ≤ 2000m (derating is necessary above 2,000m) | ||||
AC Input | AC input system | L+N+PE/220Vac | |||
Input voltage range | 90VAC ~ 290VAC | ||||
Input AC voltage frequency | 45Hz ~ 65Hz | ||||
THD | <5% (@230Vac,full load) | ||||
Power factor | ≥ 0.99 | ||||
DC Output | Rated output voltage | 24VDC | |||
Adjustable output voltage | 20VDC-30VDC continuously adjustable | ||||
System output current | 60A | 180A | 240A | 360A | |
System load regulation | ≤±0.5% | ||||
System voltage | ≤±0.5% | ||||
System stability | ≤±0.5% | ||||
Efficiency | ≥ 93.2% | ||||
Current sharing | module current sharing not more than ±5% | ||||
Weighted noise | ≤ 2mV (300Hz ~ 3400Hz) | ||||
Output distribution | MCB optional | ||||
Rectifier module unit | Rectifier hot-swap | Hot-swap available.not influencing system operation | |||
Rectifier indication | with operation.alarm.and fault indicators | ||||
Soft start time | 3s-10s | ||||
Installation method | support swappable | ||||
rectifier fault influence | Not influencing the set parameters of rectifier when rectifier at fault | ||||
Monitor module unit | Remote monitoring | With remote metering & remote control & remote signaling functions. providing standard RS485&TCP/IP Interface and 6 sets of the dry contact output port & Battery Temp.Sensor | |||
Language | Default: English | ||||
Remote control | rectifier start and close.battery test. equalize and float charging ,DIN /DO configuration and so on | ||||
Alarm functions | With AC over voltage/under voltage.DC voltage over/under.module Communication fault and over temperature alarm,Battery remove,Surge and so on | ||||
SAFTEY | Insulation resistance | Testing voltage 500VDC, Insulation Resistance ≥10M (normal atmospheric pressure, normal temperature, relative humidity <90%, no condensation) | |||
Insulation strength | Input to output: 3500VDC @1min&leak current ≤10mA Input to enclosures: 3500VDC @1min&leak current ≤10mA Output to enclosures:750VDC @1min&leak current ≤10mA | ||||
System leak current | ≤3.5mA(230Vac input) | ||||
Grounding performance requirements | The system with operating ground and protection ground.with clear mark.the resistance between the enclosures of distribution and all palpable metal components and grounding nut is not more than 0.1Ω | ||||
AC lightning protection | The equipment AC side can bear simulated lightning impulse Current of waveform 8/20μS and rated amplitude 40kA.(Optional) | ||||
Noise | ≤55dB (A) (measured at 1m distance from the equipment) | ||||
MTBF | ≥ 100000 hours |
MODEL | A220/48-50M1 | A220/48-150M3 | A220/48-200M4 | A220/48-250M5 | A220/48-300M6 | |
Configuration | 1pcs 48V/50A module +1pcs monitor | 3pcs 48V/50A module +1pcs monitor | 4pcs 48V/50A module +1pcs monitor | 5pcs 48V/50A module +1pcs monitor | 6pcs 48V/50A module +1pcs monitor | |
Environmental | Operating temperature | -40°C ~ 55°C | ||||
Storage temperature | -40°C ~ 70°C | |||||
Relative humidity | 5%~95%RH(40±2℃,no condensation) | |||||
Atmospheric pressure | 62kPa~106kPa | |||||
Altitude | ≤ 2000m (derating is necessary above 2,000m) | |||||
AC Input | AC input system | L+N+PE/220Vac | ||||
Input voltage range | 90VAC ~ 290VAC | |||||
Input AC voltage frequency | 45Hz ~ 65Hz | |||||
THD | <5% (@230Vac,full load) | |||||
Power factor | ≥ 0.99 | |||||
DC Output | Rated output voltage | 48VDC | ||||
Adjustable output voltage | 40VDC-60VDC continuously adjustable | |||||
System output current | 50A | 150A | 200A | 250A | 300A | |
System load regulation | ≤±0.5% | |||||
System voltage | ≤±0.5% | |||||
System stability | ≤±0.5% | |||||
Efficiency | ≥ 93.2% | |||||
Current sharing | module current sharing not more than ±5% | |||||
Weighted noise | ≤ 2mV (300Hz ~ 3400Hz) | |||||
Output distribution | MCB optional | |||||
Rectifier module unit | Rectifier hot-swap | Hot-swap available.not influencing system operation | ||||
Rectifier indication | with operation.alarm.and fault indicators | |||||
Soft start time | 3s-10s | |||||
Installation method | support swappable | |||||
rectifier fault influence | Not influencing the set parameters of rectifier when rectifier at fault | |||||
Monitor module unit | Remote monitoring | With remote metering & remote control & remote signaling functions. providing standard RS485&TCP/IP Interface and 6 sets of the dry contact output port & Battery Temp.Sensor | ||||
Language | Default: English | |||||
Remote control | rectifier start and close.battery test. equalize and float charging ,DIN /DO configuration and so on | |||||
Alarm functions | With AC over voltage/under voltage.DC voltage over/under.module Communication fault and over temperature alarm,Battery remove,Surge and so on | |||||
SAFTEY | Insulation resistance | Testing voltage 500VDC, Insulation Resistance ≥10M (normal atmospheric pressure, normal temperature, relative humidity <90%, no condensation) | ||||
Insulation strength | Input to output: 3500VDC @1min&leak current ≤10mA Input to enclosures: 3500VDC @1min&leak current ≤10mA Output to enclosures:750VDC @1min&leak current ≤10mA | |||||
System leak current | ≤3.5mA(230Vac input) | |||||
Grounding performance requirements | The system with operating ground and protection ground.with clear mark.the resistance between the enclosures of distribution and all palpable metal components and grounding nut is not more than 0.1Ω | |||||
AC lightning protection | The equipment AC side can bear simulated lightning impulse Current of waveform 8/20μS and rated amplitude 40kA.(Optional) | |||||
Noise | ≤55dB (A) (measured at 1m distance from the equipment) | |||||
MTBF | ≥ 100000 hours |
MODEL | A400/125-60M3 | |
Environmental | Operating temperature | -40°C ~ 55°C |
Storage temperature | -40°C ~ 70°C | |
Relative humidity | ≤ 90%RH (30°C) | |
Communication | RS485 or SNMP | |
Altitude | ≤ 2000m (derating is necessary above 2,000m) | |
AC Input | AC input system | L1+L2+L3+N/380Vac |
Input voltage range | 323-437VAC | |
Input AC voltage frequency | 45Hz ~ 65Hz | |
Max input current | ≤28.4A | |
Power factor | ≥ 0.99 | |
DC Output | Nominal output voltage | 110VDC |
Rated output voltage | 125VDC | |
Rated Output Capacity | 7.5kW | |
Output DC voltage | 90VDC ~ -150VDC | |
Output DC current | 60A | |
Voltage set-point accuracy | ≤ 1% | |
Efficiency | ≥ 93.2% | |
Noise (peak-peak) | ≤ 200mV (0 ~ 20MHz) | |
Weighted noise | ≤ 2mV (300Hz ~ 3400Hz) | |
AC Input Alarm and Protection | AC input over-voltage alarm point | Default: 280VAC ± 5VAC* |
AC input under-voltage alarm point | Default: 176VAC ± 5VAC | |
AC input over-voltage protection recovery difference | Default: 295VAC ± 5VAC, 10VAC lower than the AC input over-voltage protection point | |
AC input under-voltage protection point | Default: 180VAC ± 5VAC* | |
DC Output Alarm And Protection | DC output over-voltage alarm point | Default:149VDC ± 0.5VDC* |
DC output under-voltage alarm point | Default:90VDC ± 0.5VDC* | |
DC output over-voltage protection point | Default: 97.2VDC ± 0.5VDC* | |
LLVD | Default: 99VDC ± 0.5VDC* | |
BLVD | Default: 97.2VDC ± 0.5VDC* | |
Rectifier | Load sharing | The rectifiers can work in parallel and share the current. The unbalance is better than ± 5% rated output current. |
Derated by input (at 45°C) | The rectifier can output power of 100% with input voltage of ≥154VAC; The rectifier can output power capacity 1200W with input voltage <154VAC; Rectifiers under-voltage stop with input voltage of 85VAC |