Views: 0 Author: Site Editor Publish Time: 2024-11-04 Origin: Site
NASN TS series sine wave inverter is power frequency industrila inverter, used for rugged environments and
especially designed and produced for the enterprises in electrical power system and rail transportation, base stations, transportation, electric power, industry and safeguard critical loads in industrial applications according to their actual requirements under the condition of not only considering the spatial installation size and the automation and networking requirements for the inverter management in IT age, but also considering the influence of the noise on the personnel in offices or in machine rooms.
Output Power | 3-5KVA | 6-15KVA | 6-15KVA | 20-30KVA | 40-60KVA | 80- 120KVA | |
Input | AC input Voltage | AC220V±25% | AC220V±25% | AC380V±25% | AC380V±25% | AC380V±25% | AC380V±25% |
DC input Voltage | DC220V / DC192V / DC110V | ||||||
Frequency | 50Hz±10% | ||||||
Output | Output Voltage | AC220V±1% | |||||
Frequency | 50Hz±0.5% | ||||||
Wave Form | 100% pure sine wave, linear load harmonic distortion rate<3% | ||||||
Overload response | plus-minus protection | ||||||
Power Factor | 0.8 | ||||||
Crest Factor | 3:01 | ||||||
Efficiency | ≥90% | ||||||
Transform Time | 0ms | ||||||
Protection | Wrong wiring | Protect and Sound & light alarm | |||||
Overload | First level sound and light alarm, second level automatic bypass output after 60 seconds, automatically restored after reducing load | ||||||
Short Circuit | System automatically switches to bypass output, sound and light alarm | ||||||
Fault | System automatically switches to bypass output, sound and light alarm | ||||||
Electromagnetic immunity/compatibility | Meet GB 7260.2 | ||||||
Display | LCD screen | Input/output Parameters, Voltage, Current, Frequency, etc | |||||
Indicator | Inverter state, output state, overload, fault | ||||||
Alarm | AC input Abnormal | Sound and light alarm. Beep and display screen alarm simultaneously | |||||
DC input Abnormal | Sound and light alarm. Beep and display screen alarm simultaneously | ||||||
Bypass Abnormal | Sound and light alarm. Beep and display screen alarm simultaneously | ||||||
Overload | First level protection sound and light alarm, second level protection sound and light alarm | ||||||
System Failure | long-beep | ||||||
Communication | RS485 | Modbus standard Protocol | |||||
Dry Contact | Inverter state, bypass state, fault+AC abnormality, DC abnormality, device overload+backup | ||||||
Environment | Working Temperature | -5℃~40℃ | |||||
Relative Humidity | 0-95% No condensation | ||||||
Insulation Strength | 1500VAC 1min(input/output) | ||||||
Cooling Method | Forced Fans Cooling | ||||||
Noise | <50dB At a distance of 1 meter from the front of the device | ||||||
Dimension | 509*178*469mm | 509*267*469mm | 509*356*469mm | Cutomized |