MODEL | T48/120-XKS | |||||||
Technical Index(VA) | 0.5K | 1K | 2K | 3K | 4K | 5K | 6K | |
DC input | Rated input voltage (Vdc) | 48Vdc | ||||||
Rated input current (A) | 11 | 21 | 42 | 63 | 83 | 104 | 125 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 40V--60V Startup voltage 45.5V—57V | |||||||
Backward noise current | ≤10% | |||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 132V-90V(±10V) | ||||||
Rated input current (A) | 4.2 | 8.3 | 16.7 | 26 | 33.3 | 41.6 | 50 | |
By-pass conversion time (ms) | ≤5ms | |||||||
AC output | Rated capacity (VA) | 500 | 1K | 2K | 3K | 4K | 5K | 6K |
Rated output power (W) | 400 | 800 | 1600 | 2400 | 3200 | 4000 | 4800 | |
Inverter output voltage and frequency | 120Vac,60HZ | |||||||
Inverter output current (A) | 3.3 | 6.7 | 13.3 | 20 | 27 | 33.3 | 40 | |
Output voltage precision (V) | 120±1.5% | |||||||
Output frequency precision (Hz) | 60±0.1% | |||||||
Waveform | Pure sine wave | |||||||
Total harmonic distortion (THD) | ≤3% (linear load) | |||||||
Dynamic response time | 5% (load 0←→100%) | |||||||
Power factor (PF) | 0.8 | |||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | |||||||
Inversion efficiency (80% resistive load) | ≥85% | |||||||
By-pass conversion time (ms) | ≤5ms | |||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | ||||||
Noise (1m) | ≤40dB | |||||||
Operating environment temperature | -20℃~+50℃ | |||||||
Humidity | 0~90%, no moisture condensation | |||||||
Operating altitude (m) | ≤2000 | |||||||
Communication | RS232 and RS485, SNMP optional | |||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | |||||||
Mechanical size(mm) | Standard rack | 347*482*88 | 430*482*88 | |||||
(Depth * Width *Height) | ||||||||
Protection function | DC input reverse polarity protection | Available | ||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |