Views: 0 Author: Site Editor Publish Time: 2024-12-09 Origin: Site
NASN POWER 48V Hybrid Solar Power Telecom System project application in Colombia. 48V Hybrid Solar Power Telecom System is composed of 48Vdc hybrid rectifier system, 48Vdc to 125Vdc converter,48Vdc to 120Vac telecom inverter.
48V Hybrid Solar Power Telecom System Cabinet
48Vdc hybrid rectifier system
MODEL | B220/48-100M2HG | B220/48-200M4HG | B220/48-100M2M | B220/48-200M4M | |
Configuration | 1pcs 48V/50A AC/DC module +1pcs T4850HG MPPT module | 2pcs 48V/50A AC/DC module +2pcs T4850HG MPPT module | 1pcs 48V/50A AC/DC module +1pcs T4850M MPPT module | 2pcs 48V/50A AC/DC module +2pcs T4850M MPPT module | |
Environmental | Operating temperature | -40°C ~ 55°C | |||
Storage temperature | -40°C ~ 70°C | ||||
Relative humidity | 5%~95%RH(40±2℃,no condensation) | ||||
Atmospheric pressure | 62kPa~106kPa | ||||
Altitude | ≤ 2000m (derating is necessary above 2,000m) | ||||
Input | Rated Input Voltage | AC:110VAC / 220VAC PV:120VDC~340VDC | AC:110VAC / 220VAC PV:58VDC~120VDC | ||
Voltage range | AC:85VAC~300VAC PV:120VDC~400VDC | AC:85VAC~300VAC PV:58VDC~150VDC | |||
Frequency | 45Hz ~ 65Hz | ||||
THD | <5% (@230Vac,full load) | ||||
Power factor | ≥ 0.99 | ||||
DC Output | Rated output voltage | 48VDC | |||
Adjustable output voltage | 40VDC-60VDC continuously adjustable | ||||
System output current | 100A | 200A | 100A | 200A | |
System load regulation | ≤±0.5% | ||||
System voltage | ≤±0.5% | ||||
System stability | ≤±0.5% | ||||
Efficiency | ≥ 93.2% | ||||
Current sharing | module current sharing not more than ±5% | ||||
Weighted noise | ≤ 2mV (300Hz ~ 3400Hz) | ||||
Output distribution | MCB optional | ||||
Rectifier module unit | Rectifier hot-swap | Hot-swap available.not influencing system operation | |||
Rectifier indication | with operation.alarm.and fault indicators | ||||
Soft start time | 3s-10s | ||||
Installation method | support swappable | ||||
rectifier fault influence | Not influencing the set parameters of rectifier when rectifier at fault | ||||
Monitor module unit | Remote monitoring | With remote metering & remote control & remote signaling functions. providing standard RS485&TCP/IP Interface and 6 sets of the dry contact output port & Battery Temp.Sensor | |||
Language | Default: English | ||||
Remote control | rectifier start and close.battery test. equalize and float charging ,DIN /DO configuration and so on | ||||
Alarm functions | With AC over voltage/under voltage.DC voltage over/under.module Communication fault and over temperature alarm,Battery remove,Surge and so on | ||||
SAFTEY | Insulation resistance | Testing voltage 500VDC, Insulation Resistance ≥10M (normal atmospheric pressure, normal temperature, relative humidity <90%, no condensation) | |||
Insulation strength | Input to output: 3500VDC @1min&leak current ≤10mA Input to enclosures: 3500VDC @1min&leak current ≤10mA Output to enclosures:750VDC @1min&leak current ≤10mA | ||||
System leak current | ≤3.5mA(230Vac input) | ||||
Grounding performance requirements | The system with operating ground and protection ground.with clear mark.the resistance between the enclosures of distribution and all palpable metal components and grounding nut is not more than 0.1Ω | ||||
AC lightning protection | The equipment AC side can bear simulated lightning impulse Current of waveform 8/20μS and rated amplitude 40kA.(Optional) | ||||
Noise | ≤55dB (A) (measured at 1m distance from the equipment) | ||||
MTBF | ≥ 100000 hours |