Views: 0 Author: Site Editor Publish Time: 2025-02-05 Origin: Site
NASN telecom inverter is a new generation of dual input inverter solutions designed for the field of telecom communication applications, which is suitable for the telecom, Mobile tower, Unicom, Aviation and spaceflight, finance management,etc.
T125/220 series convert a 125 Vdc power source into 220 Vac. Available power from 500VA to 10kVA.
Features:
Powerful 1000VA/800W, 2000VA/1600W,3000VA/2400W stand-alone module
High quality pure sine wave output
Remote Power Management optional via RS-232 port,SNMP optional
High efficiency, above 85%
Built-in auto transfer switch (ATS) for increased reliability
User-friendly Status and Diagnostic LCD/LED displays,easy to operate
MODEL | T125/220-XKS | ||||||||||
Technical Index(VA) | 0.5K | 1K | 1.5K | 2K | 3K | 4K | 5K | 6K | 8K | 10K | |
DC input | Rated input voltage (Vdc) | 125Vdc | |||||||||
Rated input current (A) | 4.5 | 9 | 14 | 18 | 27 | 36 | 45 | 55 | 72.7 | 90.9 | |
Allowable range of input DC voltage (Vdc) | Cutoff voltage 90V—139V;Startup voltage 104V—131V | ||||||||||
Backward noise current | ≤10% | ||||||||||
AC by-pass input | Allowable by-pass voltage (Vac) | 260V-180V(±10V) | |||||||||
Rated input current (A) | 2.3 | 4.5 | 6.8 | 9.1 | 13.6 | 18.2 | 22.7 | 27.2 | 36.3 | 45.4 | |
By-pass conversion time (ms) | ≤5ms | ||||||||||
AC output | Rated capacity (VA) | 500 | 1K | 1.5K | 2K | 3K | 4K | 5K | 6K | 8K | 10K |
Rated output power (W) | 400 | 800 | 1200 | 1600 | 2400 | 3200 | 4000 | 4800 | 6400 | 8000 | |
Inverter output voltage and frequency | 220Vac,50HZ/60HZ | ||||||||||
Inverter output current (A) | 3.3 | 6.7 | 10 | 13.3 | 20 | 27 | 33.3 | 40 | 29 | 36.3 | |
Output voltage precision (V) | 220±1.5% | ||||||||||
Output frequency precision (Hz) | 50±0.1% Or 60±0.1% | ||||||||||
Waveform | Pure sine wave | ||||||||||
Total harmonic distortion (THD) | ≤3% (linear load) | ||||||||||
Dynamic response time | 5% (load 0←→100%) | ||||||||||
Power factor (PF) | 0.8 | ||||||||||
Overload capacity | 100%-120% 60s 121%-150% 10s | ||||||||||
Inversion efficiency (80% resistive load) | ≥85% | ||||||||||
By-pass conversion time (ms) | ≤5ms | ||||||||||
Working environment | Dielectric strength (input and output) | 1500Vac, 1 minute | |||||||||
Noise (1m) | ≤40dB | ||||||||||
Operating environment temperature | -20℃~+50℃ | ||||||||||
Humidity | 0~90%, no moisture condensation | ||||||||||
Operating altitude (m) | ≤2000 | ||||||||||
Communication | RS232 and RS485, SNMP optional | ||||||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | |||||||||
inverter status | Normal mains, normal inversion, battery under-voltage and output overload | ||||||||||
Mechanical size(mm) | Standard rack | 347*482*88 | 430*482*88 | 436*482*176 | |||||||
Depth × Width × Height) | |||||||||||
Protection function | DC input reverse polarity protection | Available | N/A | ||||||||
Normal protections | Input under-voltage and overvoltage, output overload and short circuit protections, etc. |