NASN
STS16EM STS25EM STS32EM STS40EM STS45EM
Availability: | |
---|---|
1. Adopting fully digital control, with strong anti-interference ability and fast operation speed
2. Switching time ≤ 4ms, high reliability;
3. Strong overload capacity, able to withstand full load startup;
4. Equipped with input overvoltage, undervoltage, overcurrent and other protection functions;
5. The front panel is equipped with a display screen and indicator lights to intuitively understand the STS status information;
6. Provide STS versions that can switch between live and zero lines simultaneously, with identical appearance, structure, and performance.
E: Two-road input co-zero line, can only switch the fire line;
F: Fire wire and zero line can be switched at the same time;
Model Number | STS63EM STS63FM | STS80EM STS80FM | STS100EM STS100FM | STS125EM STS125FM | |
Switch Time | ≤4ms | ||||
Input | Rated Voltage(VAC) | 220 | |||
Input Voltage Range(VAC) | 190~260 | ||||
Rated Frequency(Hz) | 50 | ||||
Power Factor | 1 | ||||
Automatic conversion threshold voltage | Undervoltage:190Vac±5Vac;Overvoltage:260Vac±5Vac | ||||
Automatic conversion threshold Frequency | Lower than:45Hz±0.2Hz;Higher:65Hz±0.2Hz | ||||
Over limit protection shutdown threshold voltage | ≤160Vac or ≥265Vac,±5V | ||||
Over limit protection shutdown threshold Frequency | ≤45Hz or ≥65Hz,±0.2Hz | ||||
Overload capacity | Continuous working @Load current≤110%; shut off @load current>110% | ||||
Output | Rated output current(A) | 63 | 80 | 100 | 125 |
Max output current(A) | 69 | 88 | 110 | 125 | |
Output power (VA/W) | 15000 | 19000 | 24000 | 27500 | |
Environment | Dielectric Strength | 2KVAC,1min | |||
Noise(1m) | ≤55dB | ||||
Working Temperature | -25~50℃ | ||||
Storage Temperature | -40~70℃ | ||||
Humidity | 0~90%,No condensation | ||||
Protection Degree | IP20 | ||||
Altitude(m) | ≤3000 | ||||
2000~3000m;Output derate by 2% for every 100m increase | |||||
Protection Function | Input undervoltage and overvoltage protection, output overload protection, over temperature protection, short circuit protection |
1. Adopting fully digital control, with strong anti-interference ability and fast operation speed
2. Switching time ≤ 4ms, high reliability;
3. Strong overload capacity, able to withstand full load startup;
4. Equipped with input overvoltage, undervoltage, overcurrent and other protection functions;
5. The front panel is equipped with a display screen and indicator lights to intuitively understand the STS status information;
6. Provide STS versions that can switch between live and zero lines simultaneously, with identical appearance, structure, and performance.
E: Two-road input co-zero line, can only switch the fire line;
F: Fire wire and zero line can be switched at the same time;
Model Number | STS63EM STS63FM | STS80EM STS80FM | STS100EM STS100FM | STS125EM STS125FM | |
Switch Time | ≤4ms | ||||
Input | Rated Voltage(VAC) | 220 | |||
Input Voltage Range(VAC) | 190~260 | ||||
Rated Frequency(Hz) | 50 | ||||
Power Factor | 1 | ||||
Automatic conversion threshold voltage | Undervoltage:190Vac±5Vac;Overvoltage:260Vac±5Vac | ||||
Automatic conversion threshold Frequency | Lower than:45Hz±0.2Hz;Higher:65Hz±0.2Hz | ||||
Over limit protection shutdown threshold voltage | ≤160Vac or ≥265Vac,±5V | ||||
Over limit protection shutdown threshold Frequency | ≤45Hz or ≥65Hz,±0.2Hz | ||||
Overload capacity | Continuous working @Load current≤110%; shut off @load current>110% | ||||
Output | Rated output current(A) | 63 | 80 | 100 | 125 |
Max output current(A) | 69 | 88 | 110 | 125 | |
Output power (VA/W) | 15000 | 19000 | 24000 | 27500 | |
Environment | Dielectric Strength | 2KVAC,1min | |||
Noise(1m) | ≤55dB | ||||
Working Temperature | -25~50℃ | ||||
Storage Temperature | -40~70℃ | ||||
Humidity | 0~90%,No condensation | ||||
Protection Degree | IP20 | ||||
Altitude(m) | ≤3000 | ||||
2000~3000m;Output derate by 2% for every 100m increase | |||||
Protection Function | Input undervoltage and overvoltage protection, output overload protection, over temperature protection, short circuit protection |