1. Up to 9pcs single-phase parallel units can be connected, with a maximum output power of 27KW/27KVA for the 3KVA model and 45KW/45KVA for the 5KVA model.
2. 9 units can be connected in parallel to support 3-phase loads, and up to 7 units can be connected for single phase load. The maximum parallel output total power of the 3KVA model can reach 27KW/27KVA, the maximum parallel output total power of the single-phase model can reach 21KW/21KVA; the maximum parallel output total power of the 5KVA model can reach 45KW/45KVA. The total parallel output power of the single-phase model can reach 35KW/35KVA.
Model | TX48-3KL | TX48-5KL | ||||||||
AC supply mode | Capacity | 3 KVA | 5 KVA | |||||||
Input voltage waveform | Sine wave (mains or generator) | |||||||||
Rated input voltage | 220 Vac | |||||||||
Low voltage line loss | 170 Vac±3V | |||||||||
Low voltage line recovery | 180 Vac±3V | |||||||||
High voltage line loss | 255 Vac±3V | |||||||||
High voltage line recovery | 245 Vac±3V | |||||||||
Maximum AC input voltage | 300 Vac | |||||||||
Rated input frequency | 50 Hz / 60 Hz (automatic detection) | |||||||||
Low frequency loss | 47.5±1 Hz | |||||||||
Low-frequency loss recovery | 48±1 Hz | |||||||||
High frequency loss | 52.5±1 Hz | |||||||||
High-frequency loss recovery | 52±1 Hz | |||||||||
Output short circuit protection | mains mode: circuit breaker Battery mode: electronic circuit | |||||||||
Efficiency (in mains mode) | > 97% (resistive load and battery charge status) | |||||||||
change-over time * | 10 ms generally | |||||||||
* When the machine is in parallel operation system, the transition time will be longer than the specification time. | ||||||||||
Inverter | Rated output capacity | 3KVA/3KW | 5KVA/5KW | |||||||
Output voltage waveform | sinusoidal wave | |||||||||
Output voltage range | 220 Vac±5% | |||||||||
output frequency | 60 Hz or 50 Hz | |||||||||
Peak efficiency | 90% | |||||||||
overload protection | 5 seconds @ 150% load; 1 min @125%~150% load; 5 min @110%~125% load | |||||||||
Sudden wave ability | 2 times the rated capacity for up to 5 seconds | |||||||||
Rated DC input voltage | 48 Vdc | |||||||||
Cold start voltage | 46.0 Vdc | |||||||||
Low DC warning voltage | ||||||||||
@ Load of <20% | 44.0 Vdc | |||||||||
@ 20% load <50%@ load 50% load | 42.8 Vdc 40.4 Vdc | |||||||||
Low DC warning to return the voltage | ||||||||||
@ Load of <20% | 46.0 Vdc | |||||||||
@ 20% ≤load <50% @ load ≥50% | 44.8 Vdc 42.4 Vdc | |||||||||
Low DC disconnection voltage | ||||||||||
@ Load of <20% | 42.0 Vdc | |||||||||
@ 20%≤ load <50% | 40.8 Vdc | |||||||||
@load ≥50% load | 38.4 Vdc | |||||||||
High DC return voltage | 58 Vdc | |||||||||
High DC disconnect voltage | 60 Vdc | |||||||||
No load-loss of electric power | <50W | |||||||||
Energy-saving mode consumes the power | <15W | |||||||||
Charger | Charging current (UPS) @ Rated input voltage | Default: 30A, maximum: 60A | ||||||||
Constant current charging voltage | 56.4 Vdc | |||||||||
floating charge voltage | 54 Vdc | |||||||||
Charging method | Stage 3 | |||||||||
charging curve | as below | |||||||||
General | Safety standards | CE | ||||||||
operating temperature range | 0° C to 40°C | |||||||||
Storage temperature range | -15°C~60°C | |||||||||
Dimensions (depth * width * height), mm | 400 x 438 x 86.3 | |||||||||
net weight (kg) | 8.7 | 9.2 |
Product appearance
1. Front panel with LCD display
2. RS-232 communication port
3. AC input terminal block
4. AC output terminal block
5. Battery input interface
6. Circuit breaker
7. Parallel communication interface (limited to parallel use only)
8. Current sharing interface (for parallel use only)
9. Dry contact
10. RS-485 Modbus communication port
11. USB communication port
1. Up to 9pcs single-phase parallel units can be connected, with a maximum output power of 27KW/27KVA for the 3KVA model and 45KW/45KVA for the 5KVA model.
2. 9 units can be connected in parallel to support 3-phase loads, and up to 7 units can be connected for single phase load. The maximum parallel output total power of the 3KVA model can reach 27KW/27KVA, the maximum parallel output total power of the single-phase model can reach 21KW/21KVA; the maximum parallel output total power of the 5KVA model can reach 45KW/45KVA. The total parallel output power of the single-phase model can reach 35KW/35KVA.
Model | TX48-3KL | TX48-5KL | ||||||||
AC supply mode | Capacity | 3 KVA | 5 KVA | |||||||
Input voltage waveform | Sine wave (mains or generator) | |||||||||
Rated input voltage | 220 Vac | |||||||||
Low voltage line loss | 170 Vac±3V | |||||||||
Low voltage line recovery | 180 Vac±3V | |||||||||
High voltage line loss | 255 Vac±3V | |||||||||
High voltage line recovery | 245 Vac±3V | |||||||||
Maximum AC input voltage | 300 Vac | |||||||||
Rated input frequency | 50 Hz / 60 Hz (automatic detection) | |||||||||
Low frequency loss | 47.5±1 Hz | |||||||||
Low-frequency loss recovery | 48±1 Hz | |||||||||
High frequency loss | 52.5±1 Hz | |||||||||
High-frequency loss recovery | 52±1 Hz | |||||||||
Output short circuit protection | mains mode: circuit breaker Battery mode: electronic circuit | |||||||||
Efficiency (in mains mode) | > 97% (resistive load and battery charge status) | |||||||||
change-over time * | 10 ms generally | |||||||||
* When the machine is in parallel operation system, the transition time will be longer than the specification time. | ||||||||||
Inverter | Rated output capacity | 3KVA/3KW | 5KVA/5KW | |||||||
Output voltage waveform | sinusoidal wave | |||||||||
Output voltage range | 220 Vac±5% | |||||||||
output frequency | 60 Hz or 50 Hz | |||||||||
Peak efficiency | 90% | |||||||||
overload protection | 5 seconds @ 150% load; 1 min @125%~150% load; 5 min @110%~125% load | |||||||||
Sudden wave ability | 2 times the rated capacity for up to 5 seconds | |||||||||
Rated DC input voltage | 48 Vdc | |||||||||
Cold start voltage | 46.0 Vdc | |||||||||
Low DC warning voltage | ||||||||||
@ Load of <20% | 44.0 Vdc | |||||||||
@ 20% load <50%@ load 50% load | 42.8 Vdc 40.4 Vdc | |||||||||
Low DC warning to return the voltage | ||||||||||
@ Load of <20% | 46.0 Vdc | |||||||||
@ 20% ≤load <50% @ load ≥50% | 44.8 Vdc 42.4 Vdc | |||||||||
Low DC disconnection voltage | ||||||||||
@ Load of <20% | 42.0 Vdc | |||||||||
@ 20%≤ load <50% | 40.8 Vdc | |||||||||
@load ≥50% load | 38.4 Vdc | |||||||||
High DC return voltage | 58 Vdc | |||||||||
High DC disconnect voltage | 60 Vdc | |||||||||
No load-loss of electric power | <50W | |||||||||
Energy-saving mode consumes the power | <15W | |||||||||
Charger | Charging current (UPS) @ Rated input voltage | Default: 30A, maximum: 60A | ||||||||
Constant current charging voltage | 56.4 Vdc | |||||||||
floating charge voltage | 54 Vdc | |||||||||
Charging method | Stage 3 | |||||||||
charging curve | as below | |||||||||
General | Safety standards | CE | ||||||||
operating temperature range | 0° C to 40°C | |||||||||
Storage temperature range | -15°C~60°C | |||||||||
Dimensions (depth * width * height), mm | 400 x 438 x 86.3 | |||||||||
net weight (kg) | 8.7 | 9.2 |
Product appearance
1. Front panel with LCD display
2. RS-232 communication port
3. AC input terminal block
4. AC output terminal block
5. Battery input interface
6. Circuit breaker
7. Parallel communication interface (limited to parallel use only)
8. Current sharing interface (for parallel use only)
9. Dry contact
10. RS-485 Modbus communication port
11. USB communication port